Re: Write Errors at EOT
1998-02-25 18:30:06
My DLT7000 shows firmware revision level 1837, via mttest.
How did you get level 60 from yours ?
Regards
Gary
----------------------------------------------------------------
Gary Bromley
Gary Bromley
Aspect Computing Pty Ltd
Tel : +61 (0)3 9230 2242
Fax : +61 (0)3 9818 1320
Email : Gary.Bromley AT Aspect.com DOT au
> ----------
> From: Bjorn Sandvik[SMTP:BHS AT STATOIL DOT NO]
> Reply To: ADSM: Dist Stor Manager
> Sent: Tuesday, 24 February 1998 20:48
> To: ADSM-L AT VM.MARIST DOT EDU
> Subject: Write Errors at EOT
>
> I suppose that you have DLT7000 drives. They need to be upgraded to
> microcode level 60. That has fixed that problem for us.
>
> Bjørn Harald Sandvik
>
> To: ADSM-L @ VM.MARIST.EDU
> cc: (bcc: Bjørn Harald Sandvik)
> From: BatteMR @ AUSTRALIA.STORTEK.COM @ INTERNET
> Date: 23.02.98 23:04:28 MST
> Subject: Write Errors at EOT
>
>
>
> Content-type: text/plain; charset=us-ascii
>
>
> ADSM'ers,
> Has anyone experienced write errors when the "End of Volume" is
> reached
> for either Tape pools or Copy Pools?
> We have received the following errors which forces the "Error State"
> to
> yes and access mode to "ReadOnly".
> **********************************************************************
> **
> *********
> 02/24/98 05:48:55 ANR1000I Migration process 45 started for
> storage
> pool BACKUPPOOL
> 02/24/98 05:52:02 ANR8341I End-of-volume reached for DLT
> volume
> DLT001
> 02/24/98 05:52:03 ANR1411W Access mode for volume DLT001 now
> set to
> "read-only" due to write error.
> **********************************************************************
> **
> *********
> All tapes are brand new and only occurs on volumes that reach the EOT
> marker.
> Any advice would be appreciated.
> Matthew Battersby
>
|
|
|