Re: Write Errors at EOT
1998-02-24 07:49:40
On Mon, 23 Feb 1998, Battersby, Matthew R wrote:
> We have received the following errors which forces the "Error State" to
> yes and access mode to "ReadOnly".
Yes, I got these all the time on the DLT7000's. I have since traded them
in on a 3575 Library with MagstarMP 3570 drives, and these drives properly
sense EOT without generating a write error. The 3570's are faster than
the DLT7000, but do not hold nearly as much data on a tape.
If I still had DLT's, I would open a problem report with IBM against the
mt device driver...
> ************************************************************************
> *********
> 02/24/98 05:48:55 ANR1000I Migration process 45 started for storage
> pool BACKUPPOOL
> 02/24/98 05:52:02 ANR8341I End-of-volume reached for DLT volume
> DLT001
> 02/24/98 05:52:03 ANR1411W Access mode for volume DLT001 now set to
> "read-only" due to write error.
>
> ************************************************************************
> *********
>
> All tapes are brand new and only occurs on volumes that reach the EOT
> marker.
>
> Any advice would be appreciated.
>
> Matthew Battersby
>
Steve (unVMix Systems Programmer/Dude) Roder
(tkssteve AT ubvm.cc.buffalo DOT edu | tkssteve AT acsu.buffalo DOT edu |
(716)645-3564 ,
| http://ubvm.cc.buffalo.edu/~tkssteve)
|
|
|