nv-l

Re: Rulesets for TEC

1999-06-16 12:19:50
Subject: Re: Rulesets for TEC
From: James Shanks <James_Shanks AT TIVOLI DOT COM>
To: nv-l AT lists.tivoli DOT com
Date: Wed, 16 Jun 1999 12:19:50 -0400
Your Event Stream Icon should be set to BlOCK not PASS.  PASS means all
events will be forwarded unless you block them. BLOCK means all will be
blocked excepted those you explicitly forward

James Shanks
Tivoli (NetView for UNIX) L3 Support



Lucy Premus <lpremus AT METLIFE DOT COM> on 06/16/99 10:54:55 AM

Please respond to Discussion of IBM NetView and POLYCENTER Manager on
      NetView <NV-L AT UCSBVM.UCSB DOT EDU>

To:   NV-L AT UCSBVM.UCSB DOT EDU
cc:    (bcc: James Shanks/Tivoli Systems)
Subject:  Rulesets for TEC





I've created my first ruleset to be used to forward selected events to TEC.
I
want to forward node down/interface down traps as well as Compaq related
traps
(which have already been defined to NetView) for specific servers (which I
have
already created two collections for).  As I said this is my first ruleset,
so
I'm not really sure what I'm doing and of course its not working as I want.
My
rulset basically contains the Event Stream Icon, configured to PASS events.
The
Event Stream icon points to a Trap Settings icon for each trap I want to
forward.  Finally each Trap Settings icon points to the 2 Query Database
Collection icons, listing all the servers I want to forward these events
for.
Thats it.  But its not working.  Events are being forwarded, but its all
events
coming into NetView, not just the ones I want.  Am I missing something in
my
ruleset or anywhere else?

<Prev in Thread] Current Thread [Next in Thread>