[Veritas-bu] Tape not mounting
2006-10-26 14:25:20
Subject: |
[Veritas-bu] Tape not mounting |
From: |
dbrown at worknetinc.com (Dave Brown) |
Date: |
Thu, 26 Oct 2006 13:25:20 -0500 |
I've had this happen when the drive needed to be cleaned
-----Original Message-----
From: veritas-bu-bounces at mailman.eng.auburn.edu
[mailto:veritas-bu-bounces at mailman.eng.auburn.edu] On Behalf Of Dave
Markham
Sent: Wednesday, October 25, 2006 6:14 AM
To: veritas-bu at mailman.eng.auburn.edu
Subject: [Veritas-bu] Tape not mounting
Netbackup 4.5mp6 on Soalris 8.
I have 2 LTO drives in my system but a backup just fails to mount a tape
in the first drive and just downs it. I have no idea why and cant see in
the logs. I have log level set to 4 and have been looking in the bptm
log but dont see anything obvious.
There is nothing in the drive also like a stuck tape.
Where do i look to find if the drive is at fault or not?
Some info below taken while the backup had started. The Drive was Up
originally.
tpconfig -d
Index DriveName DrivePath Type Shared
Status
***** ********* ********** **** ******
******
0 HPUltrium1-SCSI0 /dev/rmt/0cbn hcart No
DOWN
TLD(0) Definition DRIVE=1
1 SEAGATEULTRIUM06242-XX /dev/rmt/1cbn hcart No
UP
TLD(0) Definition DRIVE=2
Currently defined robotics are:
TLD(0) robotic path = /dev/sg/c3t0l0,
volume database host = iraya
vmoprcmd
PENDING REQUESTS
<NONE>
DRIVE STATUS
Drv Type Control User Label RecMID ExtMID Ready Wr.Enbl.
ReqId
0 hcart DOWN-TLD - No -
-
1 hcart TLD root Yes 0172L1 0172L1 Yes Yes
0
ADDITIONAL DRIVE STATUS
Drv DriveName Shared Assigned Comment
0 HPUltrium1-SCSI0 No -
1 SEAGATEULTRIUM06242- No iraya
sgscan tape
/dev/sg/c3t1l0: (/dev/rmt/0): "HP Ultrium 1-SCSI"
/dev/sg/c3t2l0: (/dev/rmt/1): "SEAGATE ULTRIUM06242-XXX"
ls -l /dev/rmt0
lrwxrwxrwx 1 root other 43 Sep 8 17:35 /dev/rmt/0 ->
../../devices/pci at 8,700000/scsi at 3,1/st at 1,0:
ls -l /dev/sg/c3t1l0
lrwxrwxrwx 1 root other 46 Apr 12 2006 /dev/sg/c3t1l0 ->
../../devices/pci at 8,700000/scsi at 3,1/sg at 1,0:raw
echo "s d" | tldtest -r /dev/sg/c3t0l0
Opening /dev/sg/c3t0l0
Enter tld commands (? returns help information)
drive 1 (addr 128) access = 1 Contains Cartridge = no
SCSI ID from drive 1 is 1
drive 2 (addr 129) access = 1 Contains Cartridge = yes
Source address = 193 (slot 2)
Barcode = 000172L1
SCSI ID from drive 2 is 2
READ_ELEMENT_STATUS complete
_______________________________________________
Veritas-bu maillist - Veritas-bu at mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
This message (including any attachments) is intended for the sole use of the
individual to whom it is addressed and may contain confidential information.
You are hereby notified that any dissemination, distribution, or duplication of
this message by someone other than the intended addressee or their designated
agent is strictly prohibited. Information included in this message that does
not relate to the specified business of Worknet shall be understood as neither
given by nor endorsed by Worknet or its employees. Any cost estimates or
estimated quotes included in this message are considered non-binding estimates
only and must not be considered final costs unless contained within an official
proposal document.
|
|
|