Reclamation error
1998-02-23 01:34:49
Hi
We have no reached a stage where we are now running out of sequential
storage on our ADSM for MVS V3.1.0 due to our reclamation's not
completing successfully. Whether this error has anything to do with the
TAPE RECLAMATION PROBLEM identified by IBM, I don't know. The ZAP
identified by IBM to solve the problem was of no help.
If anybody could share some light on the problem it would be greatly
appreciated. The error encountered can be viewed below.
02/23/1998 07:12:52 ANR9999D SSRECONS(1969): Wrong sequence number
found in
frame header.
02/23/1998 07:12:52 ANR9999D SSRECONS(1975): Actual:
Magic=E2C7C6D9,
SrvId=0, SegGroupId=38117483, SeqNum=3.
02/23/1998 07:12:52 ANR9999D SSRECONS(1982): Expected:
Magic=E2C7C6D9,
SrvId=0, SegGroupId=38117483. SeqNum=2.
02/23/1998 07:12:52 ANR9999D AFCREATE(980): Unexpected result code
(35) from
ssReconstruct.
02/23/1998 07:12:52 ANR0985I Process 3012 for SPACE RECLAMATION
running in the
BACKGROUND completed with completion state
FAILURE at
07:12:52.
Thank You
Eugene
EugeneJo AT Transnet.co DOT za
|
<Prev in Thread] |
Current Thread |
[Next in Thread>
|
- Reclamation error,
Joubert Eugene Datavia <=
|
|
|